nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Power Locks & Alarm - Erratic Operation|Page 9814 > < Power Locks & Alarm - Erratic Operation|Page 9812
Page 3
background image

a.

Open and close all the doors.

b.

Open the front two doors and moderately tap on the outer and inner door panels.

c.

Hold either front door at the "B" pillar while open and swing the door back and forth vigorously.

d.

Lightly wiggle both front inside door lock knobs with the knobs in the unlocked position.

7.

Observe the "Max" voltage indication on the CONSULT-II screen:

^

If either or both of the "Max" voltage reading(s) exceeded 0.8v, proceed to the "Lock Rod Operation and Adjustment Test" in this bulletin.

^

If neither of the "Max" voltage reading(s) exceeded 0.8v, return to "voltage during test did not exceed O.8v" in the flowchart in this bulletin.

NOTE:

If it is necessary to reset the "Max" voltage display, simply touch the CONSULT-II screen on the "Max" voltage reading.

Lock Rod Operation and Adjustment Test

1.

Remove the RH and LH door finishers.

2.

Inspect the RH & LH lock rod adjustments to the inside lock knob and center lock rod pivot (see Figure 3, below). Ensure the lock rods are not
tight or binding (lock rods should have some play when the inside lock knob is in its full unlock position). Loosen and adjust the center lock rod
pivot if necessary to allow more lock rod play, if necessary.

3.

Conclusion:

^

If the lock rods required adjustment, repeat the "Lock Signal Voltage Test", starting from step 6 to verify the front door actuator voltage
remains below 0.8v.

^

If the lock rods did not require adjustment, and the voltage reading observed at step 7 of the "Lock Signal Voltage Test" was above 0.8v,
replace the affected actuator(s) (pin 27=RH actuator, pin 28=LH actuator) with the one(s) from the Parts Information section of this bulletin.
Then, repeat the "Lock Signal Voltage Test", starting from step 6 to verify the front door actuator voltage remains below 0.8v.

Alarm Issues Tests

Power Locks & Alarm - Erratic Operation|Page 9814 > < Power Locks & Alarm - Erratic Operation|Page 9812