nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Heater & Air Conditioning System|Page 7584 > < Heater & Air Conditioning System
Page 2
background image

WARNING:  Check that all refrigerant is discharged into the recycling equipment and the pressure in the system is less than atmospheric
pressure. Then gradually loosen the discharge side hose fitting and remove it.

CAUTION:  Observe the following when replacing or cleaning refrigerant cycle components.

-

Store it in the same way at it is when mounted on the car when the compressor is removed. Failure to do so causes lubricant to enter the
low-pressure chamber.

-

Use always a torque wrench and a back-up wrench when connecting tubes.

-

Plug immediately all openings to prevent entry of dust and moisture after disconnecting tubes.

-

Connect the pipes at the final stage of the operation when installing an air conditioner in the vehicle. Never remove the seal caps of pipes
and other components until just before required for connection.

-

Allow components stored in cool areas to warm to working area temperature before removing seal caps. This prevents condensation from
forming inside A/C components.

-

Remove thoroughly moisture from the refrigeration system before charging the refrigerant.

-

Replace always used O-rings.

-

Apply lubricant to circle of the O-rings shown in illustration when connecting tube. Be careful not to apply lubricant to threaded portion.

Name : Nissan A/C System Oil Type S

-

O-ring must be closely attached to the groove portion of tube.

-

Be careful not to damage O-ring and tube when replacing the O-ring.

-

Connect tube until a click can be heard. Then tighten the nut or bolt by hand. Check that the O-ring is installed to tube correctly.

-

Perform leakage test and make sure that there is no leakage from connections after connecting line.
Disconnect that line and replace the O-ring when the refrigerant leaking point is found. Then tighten connections of seal seat to the
specified torque.

For USA and Canada

FOR USA AND CANADA : Refrigerant Connection

A new type refrigerant connection has been introduced to all refrigerant lines except the following location.

Heater & Air Conditioning System|Page 7584 > < Heater & Air Conditioning System