Component Description

The A/F sensor 1 is a planar dual-cell limit current sensor. The sensor element of the A/F sensor 1 is the combination of a Nernst concentration cell
(sensor cell) with an oxygen-pump cell, which transports ions. It has a heater in the element.

The sensor is capable of precise measurement Lamda = 1, but also in the lean and rich range. Together with its control electronics, the sensor outputs a
clear, continuous signal throughout a wide Lamda range (0.7 < Lamda < air).

The exhaust gas components diffuse through the diffusion gap at the electrode of the oxygen pump and Nernst concentration cell, where they are brought
to thermodynamic balance.

An electronic circuit controls the pump current through the oxygenpump cell so that the composition of the exhaust gas in the diffusion gap remains
constant at Lamda = 1. Therefore, the A/F sensor 1 is able to indicate air-fuel ratio by this pumping of current. In addition, a heater is integrated in the
sensor to ensure the required operating temperature of 700 - 800 °C (1,292 - 1,472 °F).