nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Visual Inspection|Page 2431 > < Visual Inspection|Page 2429
Page 2
background image

To prevent inaccurate or false readings, make sure there is no refrigerant vapor, shop chemicals, or cigarette smoke in the vicinity of the vehicle. Perform
the leak test in calm area (low air/wind movement) so that the leaking refrigerant is not dispersed.

1. Turn engine OFF.
2. Connect a suitable A/C manifold gauge set to the A/C service ports.
3. Check if the A/C refrigerant pressure is at least 345 kPa (3.52 kg/sq.cm, 50 psi) above 16 °C (61 °F). If less than specification, recover/evacuate

and recharge the system with the specified amount of refrigerant.

NOTE: At temperatures below 16 °C (61 °F), leaks may not be detected since the system may not reach 345 kPa (3.54 kg/sq.cm, 50 psi).

4. Conduct the leak test from the high side (compressor discharge a to evaporator inlet e) to the low side (evaporator drain hose f to shaft seal j).

Perform a leak check for the following areas carefully. Clean the component to be checked and move the leak detected probe completely around
the connection/component.

Compressor
Check the fitting of high and low pressure hoses, relief valve and shaft seal.

Liquid Tank
Check the refrigerant pressure sensor.

Service Valves
Check all around the service valves. Ensure service valve caps are secured on the service valves (to prevent leaks).

NOTE: After removing A/C manifold gauge set from service valves, wipe any residue from valves to prevent any false readings by leak detector.

Cooling Unit (Evaporator)
With engine OFF, turn blower fan on "High" for at least 15 seconds to dissipate any refrigerant trace in the cooling unit. Wait a minimum of 10
minutes 
accumulation time (refer to the manufacturer's recommended procedure for actual wait time) before inserting the leak detector probe into
the drain hose.

Keep the probe inserted for at least 10 seconds. Use caution not to contaminate the probe tip with water or dirt that may be in the drain hose.

5. If a leak detector detects a leak, verify at least once by blowing compressed air into area of suspected leak, then repeat check as outlined above.
6. Do not stop when one leak is found. Continue to check for additional leaks at all system components. If no leaks are found, perform steps 7 - 10.

7. Start engine.
8. Set the heater A/C control as follows;

a. A/C switch: ON
b. Face mode
c. Intake position: Recirculation
d. Max cold temperature
e. Fan speed: High

9. Run engine at 1,500 rpm for at least 2 minutes.

10. Turn engine off and perform leak check again following steps 4 through 6 above.

Refrigerant leaks should be checked immediately after stopping the engine. Begin with the leak detector at the compressor. The pressure on the
high pressure side will gradually drop after refrigerant circulation stops and pressure on the low pressure side will gradually rise, as shown in the
graph. Some leaks are more easily detected when pressure is high.

11. Before connecting ACR4 to vehicle, check ACR4 gauges. No refrigerant pressure should be displayed. If pressure is displayed, recover refrigerant

from equipment lines and then check refrigerant purity.

12. Confirm refrigerant purity in supply tank using ACR4 and refrigerant identifier.
13. Confirm refrigerant purity in vehicle A/C system using ACR4 and refrigerant identifier.

Visual Inspection|Page 2431 > < Visual Inspection|Page 2429