nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Recall R0501 - Catalytic Converter Deterioration|Page 9033 > < Recall R0501 - Catalytic Converter Deterioration|Page 9031
Page 17
background image

13.

Then, connect the battery charger to the vehicle battery.

A.

Set the charger at a low charge rate (trickle charge).

IMPORTANT

You must connect a battery charger to the vehicle battery when performing ECU reprogramming. Permanent ECU damage can occur if you
don't. Connecting a vehicle battery charger will maintain:

^

Proper CONSULT-II power supply during reprogramming-very important if the CONSULT-II battery is low.

^

Vehicle battery voltage level-especially on late model vehicles where the cooling fans come on during reprogramming.

14.

Connect CONSULT-II to the vehicle using the DLC-II cable with black Converter Box (see Figure 12).

VERY IMPORTANT:

^

Make sure the DLC-II is straight and fully plugged in to the vehicle.

^

Make sure all other DLC-II cable connections shown in Figure 12 are connected properly.

CAUTION

^

Nissan requires the use of essential tools shown in Figure 12 when performing ECM reprogramming.

^

J44200-10 "Pigtail" should not be removed from the CONSULT-II DDL Port. This "Pigtail" allows use of the stronger "quick disconnect"
cable set.

^

If cables are very often changed at the DDL Port (base) of the CONSULT-II unit, cable connector pin damage may result.

^

If there is connector pin damage, ECM reprogramming may fail. Permanent ECU damage can occur.

15.

Turn the ignition switch "ON" only (do not start the engine).

Recall R0501 - Catalytic Converter Deterioration|Page 9033 > < Recall R0501 - Catalytic Converter Deterioration|Page 9031