Sentra L4-1597cc 1.6L DOHC MFI (GA16DE) (1991)
It is important to connect the MAFS ground lead directly to the existing engine ground F9 at the intake manifold.
4.
Repeat Step 2 to confirm correct MAFS ground voltage level.
Service Tools Information
^
Digital volt meter (DVM) [Fluke # 83 or equivalent]
^
Kent-Moore Nissan Terminal Repair Kit, P/N J38751 or
Kent-Moore P/N J38751-305 Pin Extractor;
Kent-Moore P/N J38751-2 Crimping Tool
PARTS INFORMATION
NOTE:
ALL (**) part numbers listed refer to parts contained in Kent-Moore Nissan Terminal Repair Kit.