nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 1632 > < Initial Inspection and Diagnostic Overview|Page 1630
Page 56
background image

M&A BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the combination meter for damage, bend and loose connection
(unit side and connector side).
Is the inspection result normal?
YES  - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of combination meter.
2. Check the resistance between the combination meter harness connector terminals.

Is the measurement value within the specification?
YES  - GO TO 3.
NO - Repair the combination meter branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the combination meter.  See: Instrument Panel, Gauges and Warning Indicators/Testing and
Inspection/Component Tests and General Diagnostics/Combination Meter/Power Supply and Ground Circuit Inspection.
Is the inspection result normal?
YES (Present error)-Replace the combination meter.  See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and
Repair/Component Parts.
YES (Past error)-Error was detected in the combination meter branch line.
NO - Repair the power supply and the ground circuit.

CAN System (Type 1)

M&A BRANCH LINE CIRCUIT

Diagnosis Procedure

1.CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the combination meter for damage, bend and loose connection
(unit side and connector side).
Is the inspection result normal?
YES  - GO TO 2.
NO - Repair the terminal and connector.
2.CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of combination meter.
2. Check the resistance between the combination meter harness connector terminals.

Is the measurement value within the specification?
YES  - GO TO 3.
NO - Repair the combination meter branch line.
3.CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of the combination meter.  See: Instrument Panel, Gauges and Warning Indicators/Testing and
Inspection/Component Tests and General Diagnostics/Combination Meter/Power Supply and Ground Circuit Inspection.
Is the inspection result normal?
YES (Present error)-Replace the combination meter.  See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and
Repair/Component Parts.

Initial Inspection and Diagnostic Overview|Page 1632 > < Initial Inspection and Diagnostic Overview|Page 1630