4.
Make sure the ground terminal will not pull completely off of the wire.
Use moderate force to pull/push the wire in and out of the terminal (no more than 5 lbs of pull force).
a.
If the terminal pulls completely off the wire with 5 lbs of pull force, replace the solenoid valve assembly (see Parts Information).
^
Refer to the AT section of the appropriate Service Manual (ESM) for solenoid replacement.
^
Skip to step 11.
b.
If the terminal does not pull completely off of the wire, go to step 5 and continue with this procedure.
5.
Check the wire support crimp shown in Figure 5.
^
If the support crimp is up as shown in Figure 5a, push it down as shown in Figure 5b.