Diagnosis Sensor Unit: Service and Repair

Diagnosis Sensor Unit

CAUTION:
-

Before servicing SRS, turn the ignition switch OFF, disconnect both battery cables and wait for at least 3 minutes.

-

The special bolts are coated with bonding agent while the other bolt is for ground. Do not use old bolts after removal; replace with new ones.

-

Check diagnosis sensor unit for proper installation.

-

Check diagnosis sensor unit to ensure it is free of deformities, dents, cracks or rust If they show any visible signs of damage, replace them with
new ones.

-

Check diagnosis sensor unit brackets to ensure they are free of deformities or rust.

-

Replace diagnosis sensor unit if it has been dropped or sustained an impact

-

After replacement of diagnosis sensor unit, perform self-diagnosis for SRS. Refer to "DIAGNOSTIC PROCEDURE 1" for details.

REMOVAL AND INSTALLATION

1. Disconnect driver, front passenger and front side air bag module connectors. Also, disconnect front seat belt pre-tensioner connector.
2. Remove console box.
3. Disconnect diagnosis sensor unit connector.
4. Remove bolts from diagnosis sensor unit. Then remove the diagnosis sensor unit.

NOTE:  To install, reverse the removal procedure sequence.