Sentra GXE L4-1.8L (QG18DE) (2000)
Bolt length, number and location:
-
Be careful not to drop manual valve and servo release accumulator return springs.
7. Disassemble and inspect control valve assembly if necessary.
8. Remove servo release and N-D accumulators by applying compressed air if necessary.
-
Hold each piston with a clean, lint-free towel.
INSTALLATION
-
Tighten fixing bolts to specification.
7 - 9 Nm (0.7 - 0.9 kg-m, 61 - 78 inch lbs.)
-
Set manual shaft in Neutral position, then align manual plate with groove in manual valve.
-
After installing control valve assembly to transmission case, make sure that selector lever can be moved to all positions.