Sentra Hatchback Coupe L4-1597cc 1.6L SOHC (E16i) (1987)
SERVICE PROCEDURE
1.
Inspect the distance between the high pressure hose and the EAI tube. The clearance must be between 3/8 to 1/2 inch.
HIGH PRESSURE HOSE AND THE FAN MOTOR ASSEMBLY STAY
2.
Install an 8 inch heavy duty tie-wrap (P/N 01552-00411, package of 10) around the high pressure hose and the fan motor assembly stay (Figures
2).
NOTE:
Be certain the tie-wrap does not contact the fan motor harness.
FIGURE 3 - EAI TUBE
2.
Slowly tighten the tie-wrap so that the high pressure hose is pulled away from the EAI tube (Figure 3).
CAUTION: Do not cinch the the tie-wrap completely. The clearance between the high pressure hose and EAI tube must be at least 3/8 and no
more than 1/2 inch. Be certain the high pressure hose does not come in contact with the fan shroud.
WARRANTY INFORMATION
CS
PNC
CT
OP CODE
FLAT RATE
9Y
P6041
99
P60412
0.2/hr.