nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Instruments - Fuel/Temperature Gauges Erratic Operation|Page 6433 > < Campaign - Instrument Voltage Regulator|Page 6428
Page 1
background image

Instrument Power Unit: All Technical Service Bulletins
Instruments - Fuel/Temperature Gauges Erratic Operation

Reference:

Date:

TECHNICAL BULLETIN       TS86-193

November 17, 1986

Classification:

Section:                           Models:

EE86-010

Engine Electrical

1987 Sentra

INSTRUMENT VOLTAGE REGULATOR

APPLIED MODEL: 1987 Sentra (B12)

SERVICE INFORMATION

Some 1987 Sentra vehicles may have fuel and temperature gauges that show no indication or indicate high. Use the following diagnostic procedure to
check for proper operation of the instrument voltage regulator.

DIAGNOSTIC PROCEDURE

INSTRUMENT VOLTAGE REGULATOR

1.

Check output voltage of instrument voltage regulator at rear of combination meter as follows:

^

With the ignition key "ON", check voltage between the blue and black wires. Voltage should be 8.0 +/- 0.15 volts D.C. (Make sure that
battery voltage is present between yellow and black wires when checking regulator).

2.

If battery voltage is present at the yellow and black wires, and output voltage is incorrect, replace the instrument voltage regulator (see Parts
Information).

PARTS INFORMATION

Instruments - Fuel/Temperature Gauges Erratic Operation|Page 6433 > < Campaign - Instrument Voltage Regulator|Page 6428