Sentra SE-R Spec V L4-2.5L (QR25DE) (2002)
Vacuum Reservoir: Testing and Inspection
Component Inspection
VACUUM TANK
1. Disconnect vacuum hose connected to vacuum tank.
2. Connect a vacuum pump to the port A of vacuum pump.
3. Apply vacuum and make sure that vacuum exists at the port B.