Recall R0712 - ECM Update for Stalling Condition|Page 11678 > < Recall R0712 - ECM Update for Stalling Condition|Page 11676
Page 11
background image

^

If the cable is disconnected before "Complete" is displayed, you MUST restart the transfer (download) procedure; otherwise ECM damage 
can occur.

6

If the cable is disconnected during the transfer; wait for ASIST to display an "error" message, then click on "OK". Select "Backup", then
return to step 6.

11.

When transfer is complete (see Figure 9):

A.

Select (click on) "Okay", then "MAIN MENU".

B.

Turn "OFF" CONSULT-II.

C.

Disconnect the AC power cord and the Ethernet cable from CONSULT-II.

DOWNLOAD NEW DATA FROM CONSULT-II INTO THE VEHICLE (REPROGRAM ECM)

CAUTION:

^

Perform this operation in four (4) sections. DO NOT SKIP any of these sections.

^

They must be performed in order, 1 through 4.

Section 1: Connect a battery charger and CONSULT-II to the vehicle.

Section 2: Confirm the vehicle battery voltage and CONSULT-II "Charger Input".

Section 3: Perform ECM Reprogramming.

Section 4: Perform ECM Reprogram Confirmation.

Section 1: Connect a battery charger and CONSULT-II to the vehicle.

12.

Confirm the ignition switch is "OFF".

13.

Connect a battery charger to the vehicle battery.

A.

Set the charger at a low charge rate (trickle charge).

IMPORTANT

Do not perform ECU Reprogramming without connecting a battery charger to the vehicle's battery. Permanent ECU damage can occur.

Connecting a vehicle battery charger will maintain:

^

Proper CONSULT-II power supply during reprogramming-very important if the CONSULT-II battery is low.

^

Vehicle battery voltage level-especially on late model vehicles where the cooling fans come on during reprogramming.

Recall R0712 - ECM Update for Stalling Condition|Page 11678 > < Recall R0712 - ECM Update for Stalling Condition|Page 11676