nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

All Technical Service Bulletins for Air Register:|86087 > < Diagnostic Note|Page 3033
Page 1
background image

Air Register: All Technical Service Bulletins
A/C - White Flakes From Registers

Classification:
HA93-014

Reference:
NTB93-132

Date:
September 12, 1993

WHITE FLAKES FROM VENTS

APPLIED VEHICLE(S): 
All Sentra (B13) and Altima (U13)

APPLIED DATE(S): 
Sentra built before 7/29/93
Altima built before 7/29/93

SERVICE INFORMATION
Some air conditioning units may exhibit white flakes blowing from the vents for a short time when the air conditioning is first turned on. The flakes are 1
mm or less in diameter and fall on interior surfaces like a light snow. This incident can be resolved by replacing the evaporator with an improved unit
according to the procedure below.

SERVICE PROCEDURE

Use the appropriate Service Manual instructions to replace the evaporator with the countermeasure unit listed on the following page (there is no new part
number -- check for the proper date stamp indicated in the Parts Information section). When installing the new evaporator into the vehicle, make sure
that the evaporator case drain tube is correctly aligned to the drain hose and that there are no obstructions.

NOTE

To minimize the flakes remaining in the heater and air conditioning system, vacuum or blow out with compressed air any visible flakes in the heater
assembly before reinstalling the new evaporator assembly. Warm soapy water may be used to clean the inside of the evaporator case, heater case, and
all ductwork.

PARTS INFORMATION

CLAIMS INFORMATION

All Technical Service Bulletins for Air Register:|86087 > < Diagnostic Note|Page 3033