Sentra XE L4-1.8L (QG18DE) (2000)
Radiator Cooling Fan Motor: Testing and Inspection
COOLING FAN MOTORS -1 AND -2
1. Disconnect cooling fan motor harness connectors.
2. Supply cooling fan motor terminals with battery voltage and check operation.
Cooling fan motor should operate.
If NG, replace cooling fan motor.