2.
Replace the Thermo Control Module with the new one, making sure the probe is inserted in the evaporator core in the specified new location (see
Figure 1).
IMPORTANT:
^
The location of the new Thermo Control Module probe is different from the mold probe location. Make sure the new probe is inserted as shown
in Figure 1.
^
Make sure the Thermo Probe clip is fully seated and locked into position (see Figure 1).
3.
Install new 0-rings at the evaporator fittings:
^
P/N 92471-N8210 for high side (smaller tube)
^
P/N 92473-N8210 for low side (larger tube)
4.
Re-install the evaporator core assembly in reverse order of removal.
5.
Remove any residual refrigerant oil or dye from the evaporator fittings.
6.
Evacuate and re-charge the A/C system with 0.45-0.55 kg (0.99-1.21 lb) of R134a.
7.
Perform a leak check.
PARTS INFORMATION
CLAIMS INFORMATION
Submit a Primary Failed Part (PP) line claim using the claims coding shown.