EGR Backpressure Transducer: Testing and Inspection
Fig. 157 BPT Test
BACK-PRESSURE TRANSDUCER (BPT) VALVE
1.
Plug one of the "A" ports.
2.
Fill a length of clear tubing within 3 inches of ends.
3.
Attach one end of tubing to "B" port of BPT valve.
4.
Allow at least 2 inches of air between BPT Valve and water level (do not allow water to enter BPT Valve).
5.
Loop tubing into a "U" shape.
6.
Raise open end of tubing until the water level on open side of tubing is 50 mm (1.97 in.) higher than water level on the BPT side of tubing.
7.
Apply vacuum to other "A" port. Vacuum should hold steady.
8.
Slowly lower open end of tubing.
^ As water level difference drops below 50 mm (1.97 in.) vacuum should bleed off. If BPT fails above test replace valve.
EGR Valve Test
EXHAUST GAS RECIRCULATION VALVE
Apply vacuum to fitting on valve. Replace valve if the diaphragm does not hold vacuum or valve spring does not lift replace valve.