Refrigerant: Testing and Inspection

REFRIGERATION SYSTEM

Checking of Refrigerant Leaks

PRELIMINARY CHECK
Perform a visual inspection of all refrigeration parts, fittings, hoses and components for signs of A/C oil leakage, damage, and corrosion. Any A/C oil
leakage may indicate an area of refrigerant leakage. Allow extra inspection time in these areas when using either an electronic refrigerant leak detector
(J-41995) or fluorescent dye leak detector (J-42220).
If any dye is observed using a fluorescent dye leak detector (J-42220), confirm the leak using a electronic refrigerant leak detector (J-41995). It is
possible that the dye is from a prior leak that was repaired and not properly cleaned.
When searching for leaks, do not stop when one leak is found but continue to check for additional leaks at all system components and connections.
When searching for refrigerant leaks using an electronic refrigerant leak detector (J-41995), move the probe along the suspected leak area at 25 - 50
mm (1 - 2 in)
 per second and no further than 6 mm (1/4 in) from the component.

CAUTION:
Moving the electronic refrigerant leak detector probe slower and closer to the suspected leak area will improve the chances of finding a leak.