Evaporator Temperature Sensor / Switch: All Technical Service Bulletins
A/C - Low Airflow From Front Air Vents

Classification: HA09-001A

Reference: NTB09-028A

Date: November 17, 2010

LOW AIRFLOW FROM HVAC FRONT AIR VENTS

The Applied Vehicles have been amended. Please discard previous versions of this bulletin.

APPLIED VEHICLES:
2004-2008 Quest (V42)
2005-2011 Xterra (N50)
2005-2011 Pathfinder (R51)
2005-2011 Frontier (D40)
2004-2008 Titan (A60)
2004-2008 Armada (TA60)

IF YOU CONFIRM

An Applied Vehicle has low airflow coming from the HVAC front air vents due to evaporator freeze-up.

AND

The HVAC unit surface temperature around the evaporator is about 32°F (0°C) causing ice to form on the evaporator.

NOTE:

The incident may be described as:

^ Only occurring after a long drive with the HVAC on continuously and the blower set on low.

AND

^ Under conditions such as high ambient temperature and high humidity.

ACTION

^ Replace the intake sensor with the part listed in Parts Information.

^ Refer to the Service Procedure below.