When using a new terminal:
a. Slip cable seal away from terminal (if seal exist).
b. Cut wire as close to terminal as possible.
c. Slip a new cable seal onto wire (if necessary).
d. Strip 3/16" (5 mm) of insulation from wire.
e. Crimp a new terminal to the wire.
f.

Solder with rosin core solder.

g. Slide cable seal toward terminal (if equipped with a seal).
h. Crimp cable seal and insulation (if equipped with a seal).
i.

Apply grease to connectors outside the passenger compartment where the connector originally was equipped with grease.

Figure 17

To re-use a terminal or lead assembly, see previous steps c through i for repairs. Be sure to keep cable seal (if equipped) on terminal side of splice.

5. Insert lead from the back until it catches.
6. Install TPA's, CPA's and/or secondary locks, if equipped (see Figures 18 & 19).

Figure 18

Figure 19

General

There are three electrical conditions that can cause a non-working circuit: an "Open Circuit," a "Short Circuit" or a "Grounded Circuit." The break
can also be caused by intermittent or poor connections.

Open Circuit