Page 8
background image

17. If clearance restrictions do not allow the use of the J 39401-13 hold-down nuts, four M6 x 1.0 nuts with washers may be used.

18. Extend the SIR deployment harness and adapter to full length from the module.
19. Place a 12V minimum/2A minimum power source (i.e., vehicle battery) near the shorted end of the harness.

20. Connect the module (1) to the adapter (2) on the SIR deployment harness (3).
21. Firmly seat the adapter into the module connector.
22. Clear the area of people.

CAUTION:  When you are deploying an inflator module for disposal, Perform the deployment procedures in the order listed. Failure to
follow the procedures in the order listed may result in personal injury.

23. Separate the two banana plugs on the SIR deployment harness.

IMPORTANT:  
^

The rapid gas expansion involved with deploying an air bag is very loud. Notify all the people in the immediate area that you intend to deploy the

Inflator Module Replacement|Page 10139 > < Inflator Module Replacement|Page 10137