oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 627
Page 2
background image

INSTALLATION PROCEDURE

1. If removed, install the service port valve core using J 34611-A.

2. Install a NEW O-ring seal in the refrigerant pressure sensor.

Coat the O-ring seal with 525 viscosity refrigerant oil.

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Install the pressure sensor to the fitting.

Tighten
Tighten the sensor to 5 N.m (44 lb in).

4. Connect the refrigerant pressure sensor electrical connector.
5. Recharge the A/C system. Refer to Refrigerant Recovery and Recharging. See: Heating and Air Conditioning/Refrigerant/Service and Repair
6. Inspect the system operation.
7. Perform the leak test. Refer to Leak Testing.  

See: Heating and Air Conditioning/Testing and Inspection/Component Tests and General Diagnostics/Leak Testing - HVAC System - Manual

Sensors and Switches - Instrument Panel > < Refrigerant Pressure Sensor / Switch, HVAC|Specifications|Page 627