Air Duct: All Technical Service Bulletins
A/C - Noise/Inadequate Air Flow

File In Section: 01 - HVAC 

Bulletin No.: 00-01-39-002

Date: September, 2000

TECHNICAL

Subject:
Noise in HVAC System/Insufficient Air Flow From HVAC System/HVAC System Pulling/Lifting Papers/Debris From Glovebox Bin (Install Barrier
Material)

Models:
2001 Oldsmobile Aurora 
Built Prior to VIN Breakpoint 14123892

Condition

Some customers may comment on the following conditions when the HVAC system is in the RECIRC mode:

^

Noise in the HVAC system near the IP storage compartment (glovebox).

^

Insufficient air flow from the HVAC system or the HVAC does not operate properly.

^

Papers/debris are being pulled/lifted/drawn from the IP storage compartment (glovebox) bin.

Cause

The HVAC module, when in the RECIRC mode, may have sufficient strength to pull/lift/draw papers/debris out of the top of the IP storage compartment
(glovebox) bin when the glovebox door is closed.

The ingestion of the papers/debris may cause noise, insufficient air flow and/or the HVAC module to be inoperative.

Correction

Install a 20.3 cm x 25.4 cm (8 in x 10 in) sheet of barrier material, Adhesive Flocking Tape, P/N 12378189 (P/N 10953434 in Canada), between the IP
storage compartment (glovebox) bin and the air duct in order to close off the glovebox bin opening.

Repair Procedure

1.

Fold the 20.3 cm x 25.4 cm (8 in x 10 in) sheet of Adhesive Flocking Tape, P/N 12378189 (P/N 10953434 in Canada), lengthwise into three
sections with the paper backing (1) to the outside.