Aurora V6-214 3.5L VIN H SFI (2001)
Hose/Line HVAC: Service and Repair
Condenser Tube Replacement
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Loosen the Condenser tube nut (2).
3. Disconnect the condenser tube (2) from the orifice valve hose.
4. Remove the right headlamp.
5. Disconnect the condenser tube from the condenser.
6. Remove the condenser tube.
INSTALLATION PROCEDURE
IMPORTANT: Inspect the seal washers for damage before reinstalling the A/C lines and hoses.
If any damage is noted during inspection, the suspect seal must be replaced.
Flat washer type seals do not require lubrication.