Important:  Care should be taken when installing the water housing crossover bolts, so that the gaskets are in the correct position.

3. Place the water housing crossover in position.

Notice:  Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners
requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use
paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint
clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid
damage to parts and systems.

4. Hand start the water housing crossover bolts.

Tighten
Tighten water housing crossover bolts in sequence (1-6) to 25 Nm (18 lb ft).