Aurora V6-214 3.5L VIN H SFI (2001)
Hose/Line HVAC: Service and Repair
Evaporator Hose Assembly Replacement
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Loosen the evaporator hose nut.
3. Disconnect the A/C evaporator hose (2) from the orifice valve.
4. Remove the evaporator hose nut.
5. Disconnect the A/C evaporator hose from the accumulator.