Ignition 3 Input

The scan tool displays Active/Inactive. The scan tool displays Active when the Ignition 3 input (run) circuit of the module receives a battery voltage
signal from the ignition switch.

Ignition/Crank/Run

The scan tool displays Active/Inactive. The scan tool displays Active when the Crank/Run, Run and Unlock circuits of the DIM receives a battery
voltage signal from the ignition switch.

Inadvertent Power Input

 The scan tool displays On/Off. Display indicates the state of the inadvertent power.

Inadvertent Power Relay

The scan tool displays On/Off. Display indicates the commanded state of the inadvertent power relay.

Incandescent Dim #1

The scan tool displays On/Off. Display indicates the state of the incandescent lamp ground circuit.

Inside Air Temp-HVAC Sensors

The scan tool displays -40 to +60° C (-40 to +140° F). The output of the inside air temperature sensor.

Inside Air Temp-Open/Short Data

The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. 0 counts indicates a short to ground, 255 counts
indicates an open circuit.

Interior DIM Pot

The scan tool displays the amount of interior dimming requested in Counts.

Interior Lamp Switch

The scan tool displays OFF/AUTO/ON - Display indicates the position of the interior lamp switch - AUTO is the normal operating range.

Jullian Date of Build

The scan tool displays 3 digit numeric number. This is the day of the year that the module was built

Key In Ignition

The scan tool displays Yes/No. The scan too displays Yes when the key is in the ignition and the instrument panel integration module (IPM) receives a
signal from the ignition switch.

Left A/C Duct Temp-HVAC Sensors

The scan tool displays -40 to +150° C (-40 to +300° F). The display represents the output of the LH A/C duct temperature sensor.

Left A/C Duct Temp-Open/Short Data

The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. 0 counts indicates a short to ground, 255 counts
indicates an open circuit. The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. 0 counts indicates a
short to ground, 255 counts indicates an open circuit.

Left Duct Temp Desired

The scan tool displays 40 to 150°C (-40 to 300° F). The output of the LH A/C duct temperature sensor.

Left Htr. Duct Temp-HVAC Sensors

The scan tool displays -40 to 150° C (40 to 300° F). The output of the LH HTR duct temperature sensor.

Left Htr. Duct Temp-Open/Short Data

The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. A 0 count indicates a short to ground, 255
counts indicates an open circuit.

Left Program Number

The scan tool displays 0-255 counts. Display indicates the commanded temperature setting.

Initial Inspection and Diagnostic Overview|Page 4771 > < Initial Inspection and Diagnostic Overview|Page 4769