oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 29 > < Diagram Information and Instructions|Page 27
Page 17
background image

4. Re-assemble the cable.

^

Rewrap the conductors with the mylar tape.

^

Use caution not to wrap the drain wire in the tape (1).

^

Follow the splicing instructions for copper wire and splice the drain wire.

^

Wrap the drain wire around the conductors and tape with mylar tape.

IMPORTANT:  Apply the mylar tape with the aluminum side inward. This ensures good electrical contact with the drain wire.

5. Tape over the entire cable. Use a winding motion when you apply the tape.

Connector Position Assurance Locks

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of all the SIR system electrical connectors. The CPA
ensures that the connector halves cannot vibrate apart. You must have the CPA in place in order to ensure good contact between the SIR mating
terminals.

Terminal Position Assurance Locks

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Push to Seat Connectors

TERMINAL REMOVAL

Follow the steps below in order to repair push to seat connectors.

Diagram Information and Instructions|Page 29 > < Diagram Information and Instructions|Page 27