Aurora V6-214 3.5L VIN H SFI (2001)
Notice: Refer to Fastener Notice in Service Precautions.
1. Check the TORX (R) head bolts (1) on the hydraulic pump housing (2) for tightness.
-
Tighten the TORX (R) head bolts (1) to 20 - 25 Nm (15 - 18 ft. lbs.).
2. Check the valve bore plug (1) and the O-ring union fitting.
-
Tighten the valve bore plug (1) to 50 - 60 Nm (37 - 44 ft. lbs.).
3. Lubricate the new O-ring seal (2) with power steering fluid.
4. Connect the O-ring seal (2) to the reservoir (1).
Important: Align the mounting hole on the reservoir (2) correctly with the hole on the top of the pump housing assembly (3) to prevent damage.