oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Automatic Control|Page 9023 > < Automatic Control|Page 9021
Page 9
background image

6. Remove the HVAC B fuse for a minimum of 10 seconds.
7. Re-install the HVAC B fuse.
8. Place the ignition switch in the RUN position.
9. Wait 40 seconds for the auxiliary HVAC control module to re-calibrate.

10. Verify that no DTCs have set as current DTCs.

Re-Calibrating Actuators (Primary)

When replacing the HVAC control module it will be necessary to allow the HVAC control module to perform a re-calibration process. When installing
the HVAC control module be sure to perform the following:

1. Place the ignition switch to the OFF position.
2. Disconnect the scan tool.
3. Install the HVAC control module.
4. Re-connect all previously disconnected components.
5. Place the ignition switch in the RUN position.
6. Wait 40 seconds for the HVAC control module to re-calibrate.
7. Verify that no DTCs have set as current DTCs.

When replacing the motor assembly it will be necessary to allow the HVAC control module to perform a re-calibration process. When installing the
motor assembly be sure to perform one of the following:

Preferred Method (W/Scan Tool)
1. Clear all DTCs
2. Place the ignition switch in the OFF position.
3. Install the motor assembly.
4. Re-connect all previously disconnected components.
5. Place the ignition switch in the RUN position.
6. With the scan tool, initiate the Motor Re-calibration feature of the HVAC module Special Functions menu.
7. Verify that no DTCs have set as current DTCs.

Alternate Method (W/O Scan Tool)
1. Clear all DTCs
2. Place the ignition switch to the OFF position.
3. Disconnect the scan tool.
4. Install the motor assembly.
5. Re-connect all previously disconnected components.
6. Remove the HVAC B fuse for a minimum of 10 seconds.
7. Re-install the HVAC B fuse.
8. Place the ignition switch in the RUN position.
9. Wait 40 seconds for the HVAC control module to re-calibrate.

10. Verify that no DTCs have set as current DTCs.

Recirculation Actuator

REMOVAL PROCEDURE

1. Remove the HVAC module assembly.
2. Remove the air inlet assembly screws.
3. Remove the air inlet assembly.

Automatic Control|Page 9023 > < Automatic Control|Page 9021