1. Connect the crankcase clean air hose to the air cleaner outlet resonator (2).
2. Connect the crankcase clean air hose to the valve cover port.

Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants,
or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may
damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

3. Install the 2 resonator to engine bolts (4) to the air cleaner outlet resonator (5). Tighten the bolts to 6 Nm (63 lb in).

PCV Valve Hose|Service and Repair|Page 5170 > < PCV Valve Hose|Service and Repair|Page 5168