Bravada 2WD L6-4.2L VIN S (2002)
Resonator: Service and Repair
Air Cleaner Resonator Outlet Duct Replacement
REMOVAL PROCEDURE
1. Remove the air cleaner element.
2. Disconnect the intake air temperature (IAT) sensor (3) electrical connector.
3. Loosen duct clamp (1) on the air cleaner side of the air cleaner outlet resonator (2).
4. Remove the air cleaner outlet duct.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the air cleaner outlet duct onto the air cleaner outlet resonator (2).
Tighten
Tighten the duct clamp (1) to 4 N.m (35 lb in).
2. Reconnect the IAT electrical connector.
3. Install the air cleaner element.