background image

TERMINAL REPAIR

1. Slip the cable seal away from the terminal.
2. Cut the wire as close to the terminal as possible.
3. Slip a new cable seal onto the wire.
4. Strip 5 mm (3/16 in) of insulation from the wire.
5. Crimp a new terminal to the wire.
6. Solder the crimp with rosin core solder.
7. Slide the cable seal toward the terminal.
8. Crimp the cable seal and the insulation.
9. If the connector is outside of the passenger compartment, apply grease to the connector.

REINSTALLING TERMINAL

1. In order to reuse a terminal or lead assembly. Refer to Wiring Repairs.
2. Ensure that the cable seal is kept on the terminal side of the splice.
3. Insert the lead from the back until it catches.
4. Install the TPA, CPA and/or the secondary locks.

Repairing Connector Terminals

TOOLS REQUIRED

J 38125-B Terminal Repair kit

Use the following repair procedures in order to repair the following.

^

Push to Seat terminals

^

Pull to Seat terminals

^

Weather Pack(R) terminals

Some terminals do not require all of the steps shown. Skip the steps that do not apply for your immediate terminal repair. The J 38125-B contains further
information.

1. Cut off the terminal between the core and the insulation crimp. Minimize any wire loss.

For Weather Pack(R) terminals, remove the seal.

2. Apply the correct seal per gage size of the wire.

For Weather Pack(R) terminals, slide the seal back along the wire in order to enable insulation removal.

3. Remove the insulation.
4. For Weather Pack(R) terminals only, align the seal with the end of the cable insulation.
5. Position the strip in the terminal

For Weather Pack(R) terminals, position the strip and seal in the terminal.

6. Hand crimp the core wings.
7. Hand crimp the insulation wings.

For Weather Pack(R) terminals, hand crimp the insulation wings around the seal and the cable.

8. Solder all of the hand crimp terminals excepting Micro-Pack 100 World terminals. Soldering Micro-Pack 100 World terminals may damage the

terminal.

Terminal Position Assurance Locks

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely