Refrigerant Pressure Sensor / Switch: Technical Service Bulletins
A/C - O-Ring Push Out During Installation

SUBJECT:

SERVICE PROCEDURE O-RING PUSH OUT DURING HI SIDE SWITCH INSTALLATION

MODELS/YEARS:

1988-1990 CUTLASS CALAIS AND 1988 FIRENZA

MODELS WITH C60

NUMBER:

90-T-04

CORP. REF. NO: 971206

DATE:

August 1989

SECTION:

1B

Figure 1

Due to a stack up of tolerances between the high side pressure switch or sensor and the high side port, some difficulty may be encountered when
replacing a switch or sensor with the refrigerant system changed. The Schraeder (R) valve may be depressed before the O-ring is captured by the switch
resulting in the Oring being pushed out of its sealing area causing a leak.

On vehicles with this condition, the O-ring may be held in place by wrapping a string around the inboard side of the switch port while the switch is being
screwed on (refer to Figure 1). This will hold the O-ring in the switch port while the Schraeder (R) valve is being depressed. Once the O-ring is captured,
the string should be removed and the switch screwed on until fully seated. The joint should then be leak checked with a refrigerant detector.

Redesigned parts will be in production during the 1990 model year.