Cutlass Ciera Cruiser V6-3100 3.1L MFI VIN M (1994)
Backup Lamp: Description and Operation
Voltage is applied at all times through the TURN/BU Fuse to the Park/Neutral Position (PNP) Switch. Whenever the gear selector lever is shifted to
"REVERSE," the Switch closes and voltage is applied to the Backup Lights.