Mixture Control Solenoid: Description and Operation

NOTE:  For more information See Fuel Control System Operation.

The ECM controls the air/fuel mixture through the MC solenoid ground circuit--actuating the metering rods.
-

When the MC solenoid is energized (down position), fuel flow is reduced providing leaner mixtures. 

-

When the solenoid circuit is open (up position), more fuel is allowed to flow, providing richer mixtures. 

The ECM cycles the MC solenoid "ON and OFF" at a fixed rate of 10 times per second. 
The air/fuel mixture is adjusted by varying the amount of time the solenoid is energized per cycle--solenoid dwell.

NOTE:  Solenoid dwell can be read using most dwell meters SEE Testing and Inspection. If engine operation changes when a dwell meter is connected
to the mixture control solenoid use a different meter. Meters with three leads are more likely to be able to measure solenoid dwell correctly than those
with two leads.