oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Lateral Accelerometer > < Hydraulic Control Assembly - Antilock Brakes|Locations|Page 7269
Page 2
background image

REMOVE OR DISCONNECT

1. Battery negative Cable.
2. Air cleaner assembly and Powertrain Control Module (PCM) cover.
3. EBCM/EBTCM harness connector and BPMV motor ground cable connector.
4. Brake pipe fittings.

IMPORTANT:  Note location of brake pipes for aid during installation.

NOTICE:  When removing the brake pressure modulator valve, protect vehicle exterior from possible brake fluid spillage.

NOTICE:  Reposition brake pipes as necessary to remove brake pressure modulator valve. Excessive bending may cause damage to the brake pipes.

CLEAN

^

Any brake fluid spillage from the brake pressure modulator valve.

5. EBCM/EBTCM bracket and mounting bolt.
6. Upper BPMV bracket from frame rail.
7. EBCM/BPMV assembly from vehicle.
8. Four EBCM/EBTCM to BPMV bolts.
9. Separate EBCM/EBTCM from BPMV by pulling rearward until separated.

CAUTION:  Do not pry EBCM/EBTCM. Be careful not to damage seal (if reusing module). If seal is damaged during removal, repair
damaged area using GM P/N 123456739 silicone sealer or replace EBCM/EBTCM.

INSTALL OR CONNECT

1. EBCM/EBTCM to BPMV.

CLEAN

^

EBCM/EBTCM seal and BPMV gasket surface with alcohol.

TIGHTEN

^

Four mounting bolts to 4.5 Nm (40 lb. in.).

^

Center bolt with bracket to 14 Nm (10 lb. ft.).

2. BPMV bracket to BPMV.

^

If a new brake BPMV is being installed, remove shipping plugs from valve openings.

CAUTION:  Make sure brake pipes are correctly connected to brake pressure modulator valve. If brake pipes are switched by mistake,
wheel lockup will occur and personal injury may result. The only two ways this condition can be detected are by using the Tech I Diagnostic
Tester or by doing an antilock stop.

3. EBCM/BPMV assembly into vehicle.

TIGHTEN

^

Frame rail bracket bolts to 12 Nm (106 lb. in.).

4. Brake pipe fittings.

IMPORTANT:  Use locations noted during removal.

TIGHTEN

^

Brake pipe fittings at Brake Pressure Modulator Valve to 18 Nm (13 lb. ft.).

5. EBCM/EBTCM harness connector and motor ground cable connector.

^

Lock Tab.

6. Air cleaner assembly and PCM cover.
7. Battery negative cable.
8. Fill and bleed hydraulic brake system.
9. Perform "Auto Bleed Procedure".

10. Perform "ABS/TCS Functional Check".