Intrigue V6-3.8L VIN K (1998)
Air Door Actuator / Motor: Service and Repair
Air Inlet Actuator
Without Dual Zone A/C
Removal Procedure
1. Remove the instrument panel compartment.
2. Remove the right instrument panel insulator.
3. Remove the vacuum electrical solenoid.
4. Disconnect the vacuum line from the air inlet vacuum actuator.
5. Lift to release the air inlet vacuum actuator retaining tab and slide off mounting bracket.
6. Disconnect the vacuum actuator plunger rod from the air inlet valve lever and remove the air inlet vacuum actuator.
Installation Procedure
1. Connect the air inlet vacuum actuator plunger rod to the air inlet valve, then extend the plunger.
Important: During installation, ensure that the air inlet vacuum actuator retaining tab is positioned above the mating base on the HVAC module case.
2. Push the vacuum actuator toward the HVAC module case to secure the retaining tab.
Important: Check that the vacuum actuator pushrod is not binding on the air inlet lever.
3. Connect the vacuum harness connector to the air inlet vacuum actuator.
4. Install the vacuum electrical solenoid.
5. Install the right instrument panel insulator.
6. Install the instrument panel compartment.
With Dual Zone A/C