oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Air Inlet Actuator|Page 10092 > < Air Inlet Actuator|Page 10090
Page 4
background image

6. Remove the temperature valve electric actuator.

Installation Procedure

1. Position the temperature valve electric actuator, then align the slots in the electric actuator driver to the flats on the temperature valve shaft.
2. Slide the electric actuator driver onto the shaft, while aligning the actuator locating hole to the forward alignment pin on the HVAC module case.

The actuator driver should completely seat onto the temperature valve shaft and the mounting holes should be flush with the mounting bosses on
the HVAC module case.

3. Install the mounting screws to the temperature valve electric actuator.

Tighten
Tighten the screws to 1.5 N.m (13 lb in).

4. Connect the electrical connector to the temperature valve electric actuator.
5. Install the knee bolster. 
6. Install the left instrument panel insulator. 
7. Connect the negative battery cable. 

Air Inlet Actuator|Page 10092 > < Air Inlet Actuator|Page 10090