oldsmobile Workshop Repair Guides

Oldsmobile Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 733 > < Diagram Information and Instructions|Page 731
Page 9
background image

J 39200 digital multimeter.

The J 39200 Instruction Manual is a good source of information and should be read thoroughly upon receipt of the DMM as well as kept on hand for
reference during new procedures.

A DMM should be used instead of a test light to check for voltage. While a test light shows whether voltage is present, a DMM indicates how much
voltage is present.

When testing for voltage or continuity at the connection, it is not necessary to separate the two halves of the connector. Unless testing a Weather
Pack(R), a Metri Pack(R) or other sealed system, always probe the connector from the back. Always check both sides of the connector. An accumulation
of dirt and corrosion between contact surfaces is sometimes a cause of electrical problems.

The ohmmeter function on a DMM shows how much resistance exists between two points along a circuit. Low resistance in a circuit means good
continuity.

IMPORTANT: Disconnect the battery when measuring resistance with a DMM. This prevents incorrect readings.

DMMs apply such a small voltage to measure resistance that the presence of voltages can upset a resistance reading.

Diodes and solid state components in a circuit can cause a DMM to display a false reading. To find out if a component is affecting a measurement take a
reading once, then reverse the leads and take a second reading. If the readings differ the solid state component is affecting the measurement. Following
are examples of the various methods of connecting the DMM to the circuit to be checked:

^

Backprobe both ends of the connector and either hold the leads in place while manipulating the connector or tape the leads to the harness for
continuous monitoring while you perform other operations or test driving.

^

Disconnect the harness at both ends of the suspected circuit where it connects either to a component or to other harnesses.

Use the J 35616-A Connector Test Adapter Kit in order to connect the DMM to the circuit.

^

If the system that is being diagnosed has a specified pinout or breakout box, it may be used in order to simplify connecting the DMM to the circuit
or for checking multiple circuits quickly.

Short Finder

The J 8681-A can locate hidden shorts to ground. The short finder creates a pulsing magnetic field in the shorted circuit and shows the location of the
short through the body trim or sheet metal.

Probing Electrical Connectors

FRONTPROBE

IMPORTANT:

^

When reconnecting connectors or replacing terminals always be sure to reinstall the Connector Position Assurance (CPA) and Terminal Position
Assurance (TPA).

^

After frontprobing any connector, check for terminal damage. It terminal damage is suspected, check for proper terminal contact.

When frontprobing connectors use a mating terminal adapter from the J 35616-A Connector Test Adapter Kit. Using the proper adapters ensures
that proper terminal contact integrity is maintained.

Frontprobe connector terminals only when specifically required in diagnostic procedures. Because frontprobing can be a source of damage to
connector terminals. Use extra care in order to avoid deforming the terminal, either by forcing the test probe too far into the cavity or by using too
large of a test probe.

BACKPROBE

IMPORTANT:

^

Do not backprobe a sealed connector.

^

After backprobing any connector, check for terminal damage. If terminal damage is suspected, check for proper terminal contact.

Connector Test Adapters

NOTICE: Do not use paper clips or other substitutes as they can damage terminals and cause incorrect measurements.

The J 35616-A Connect Test Adapter Kit contains various terminal pigtails for probing terminals.

Connector test adapter kit allows the DMM to conduct tests and measurements at separated connectors, fuse, or relay terminals.

Fused Jumper Wire

IMPORTANT: A fused jumper may not protect solid state components from being damaged.

The J 36169 fused jumper is available with small clamp connectors providing adaptation to most connectors without damage. This fused jumper wire is