Toronado V8-350 5.7L DSL (1983)
FIGURE 1
b)
Apply a bead of 3M 8011 or equivalent into the new weatherstrip carrier opening (Figure 1). Allow to dry until adhesive becomes tacky
(approximately 5 minutes).
c)
Install new weatherstrip to flange and allow a minimum of 3 hours before closing lid.
7.
Close lid and retest for water leaks. If water leaks are found, apply additional 3M 8011 or equivalent under weatherstrip outer lip.
WARRANTY INFORMATION
Labor
Time
Trouble
Operation
Allowance
Code
T0077
.6 Hr.
92