peugeot Workshop Repair Guides

Peugeot Workshop Service and Repair Manuals

A/T - Vibration After Torque Converter Lock-Up|Page 2233 > < A/T - Vibration After Torque Converter Lock-Up
Page 2
background image

FIGURE 1

5.

Remove the WK housing from the valve body, Fig. 1 by removing 6 bolts from opposite side where the WK housing is mounted. Try to remove
the WK separator plate with WK housing so that you do not lose the check ball seated in the channel of the WK Housing.

6.

Pull clip holding "Hysterese Spring" (see arrow in Fig. 1) and remove spring; install new spring and reinsert spring retaining clip.

FIGURE 2

7.

Remount WK housing on valve body (6 bolts) insuring the check ball is seated in channel as shown in Fig. 2. Torque bolts to 0.6 daNm (4.35 Ft.
Lbs.).

A/T - Vibration After Torque Converter Lock-Up|Page 2233 > < A/T - Vibration After Torque Converter Lock-Up