peugeot Workshop Repair Guides

Peugeot Workshop Service and Repair Manuals

Vacuum Advance Cut-Out System|Page 1080 > < Vacuum Advance Cut-Out System|Page 1078
Page 4
background image

Fig. 12 Connecting vacuum pump to electro valve

Diagnosis

1.

Disconnect T-hose, Fig. 11, from electro valve.

2.

Connect a suitable hand held vacuum pump, Fig. 12, to the electro valve.

3.

Start engine and increase engine speed slightly. Pump gauge should indicate vacuum.

4.

Release throttle and allow engine to return to idle. No vacuum should be indicated.

5.

If vacuum is obtained with engine idling, check condition and/or adjustment of micro switch, operation of twin speed relay, Fig. 8, and electro
valve.

Vacuum Advance Cut-Out System|Page 1080 > < Vacuum Advance Cut-Out System|Page 1078