plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Hydraulic Control Unit (HCU) Replacement|Page 5002 > < Hydraulic Control Unit (HCU) Replacement|Page 5000
Page 8
background image

Ground Cable Attachment At Strut Tower

11. Install the remote ground cable onto the ground stud located on left shock tower. Install the remote ground cable attaching nut and tighten to a

torque of 28 Nm (250 inch lbs.).

12. Bleed the base brakes and the ABS brakes hydraulic system. Refer to Antilock Brake System Service and Repair for the proper bleeding

procedure.

13. Road test vehicle to ensure proper operation of the base and ABS systems.

Hydraulic Control Unit (HCU) Replacement|Page 5002 > < Hydraulic Control Unit (HCU) Replacement|Page 5000