Liquid Line From Expansion Valve

3. Remove liquid line at filter/drier from expansion valve.

Receiver/Drier Bracket

4. Remove filter/drier bracket bolt at base of filter/drier.
5. Cap liquid line and condenser threaded fitting while system is open to prevent moisture from entering system.

INSTALLATION

CAUTION:  When installing new filter/drier do not leave open to atmosphere for a long period of time. The filter/drier contains moisture
absorbing materials which will absorb moisture in the atmosphere.

For installation, reverse the above procedures.