plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 985 > < Diagram Information and Instructions|Page 983
Page 10
background image

When using a circuit tester to perform continuity or voltage checks on connector terminals, insert the test probe from the harness side.

If the connector is a sealed connector, insert the test probe in through the hole in the rubber cap for the electrical wires, being careful not to damage the
insulation of the wires; continue to insert the test probe until it contacts the terminal.

When shield connectors are connected or disconnected, pay attention to the following points.

1. If there are mud, dirt, dust and other deposits on part A (0-ring), clean in silicone oil. If O-ring is damaged, replace.

2. If there are oil, mud, dirt, dust and other deposits on surfaces B, clean in silicone oil.

3. Check to ensure that part C (rubber plug) is held securely in the connector housing.

Diagram Information and Instructions|Page 985 > < Diagram Information and Instructions|Page 983