plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Malfunction Indicator Lamp > < Main Relay (Computer/Fuel System)|Locations|Page 1932
Page 2
background image

Figure 17. Coil L3

3.

Check continuity between control relay terminals, with relay coil energized and not energized as shown. To energize coil, L3, apply battery
voltage across terminals 8 and 6.

4.

If test results are not satisfactory, replace control relay.