plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Fuel System - Hard Hot Starts|Page 609 > < Fuel System - Hard Hot Starts|Page 603
Page 1
background image

Air Cleaner Housing: Customer Interest
Fuel System - Hard Hot Starts

Models

1981-1988 "M" Body Vehicles Equipped With 5.2L 4V Engines

Subject

Hard Hot Starts

Index

DRIVEABILITY

Date

March 7, 1988

No.

18-08-88

P-856 (C18-10)
SYMPTOM/CONDITION

Long engine crank times with black smoke coming from the exhaust following a hot engine shut down. This condition may occur if starting is attempted
10 to 45 minutes after engine shut down in all temperatures.

PARTS REQUIRED

1

Bolt - M6 x 1 x 14

PN 5240437

1

Nut - M6 x 1

PN 6500274

1

Authorized Modification Label

PN 4275086

Parts to be ordered separately.

REPAIR PROCEDURE

This repair involves installing a bolt to hold the vapor containment door open. This reduces the build up of fuel vapors inside the air cleaner.

1.

While holding the vapor containment trap door open, drill a 1/4" hole through both the round dimple of the air cleaner snorkel and the trap door.

The vapor containment trap door is located in the air cleaner snorkel that has the heated air vacuum motor.