plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Air Injection Pump|Testing and Inspection > < Air Injection Pump|Locations
Page 1
background image

Air Injection Pump: Description and Operation

Fig. 2 Air injection pump with integral centrifugal air filter and pressure relief valve

    The belt driven air pump, Fig. 2, is mounted on the front of the engine. Intake air passes through a centrifugal fan at the front of the pump, where
foreign materials are separated from the air by a centrifugal force. Air is delivered to the air injection manifold and tube assembly by a rubber hose
through the air switching valve mounted on the rear of the pump.

Air Injection Pump|Testing and Inspection > < Air Injection Pump|Locations